Pump Group Energy Efficiency Analysis at a Lift Pumping Station

Lift Pumping Station · AquaBrain™ Operating Data Analysis

5 pumps
18 days of operating data
26,000 minute-level records
approx. 13%lower specific energy consumption of the most efficient combination vs. the duty combination

Background

The station is equipped with 5 pumps and normally operates with a fixed duty pump combination. The owner wanted to understand the energy efficiency of pump operation and the potential for optimization.

Method

The AquaBrain™ platform was used to analyze approximately 26,000 minute-level operating records covering 18 days. Specific energy consumption, operating hours and power factor were calculated for each pump combination, and data quality was checked.

Key Findings

  • The most energy-efficient pump combination had about 13% lower specific energy consumption than the usual duty combination, but accounted for less than 4% of actual operating time.
  • Two fixed-speed pumps running at mains frequency had a power factor of only 0.71–0.76, leaving room for reactive power compensation.
  • A frequency signal conversion error was found for one pump, affecting data accuracy.

Next Steps

These findings translate directly into pump scheduling optimization, reactive power compensation and data governance measures, and can be executed in closed loop through the pump group optimization system.